Projecte

General

Perfil

Actions

Error #393

tancat

Asymetric BMX6 link on ethernet bridge interface

Afegit per Victor Oncins fa més de 7 anys. Actualitzat fa aproximadament 7 anys.

Estat:
Tancat
Prioritat:
Normal
Categoria:
Network
Versió prevista:
-
Inici:
08-12-2016
Data de venciment:
% realitzat:

100%

Temps previst:
Temps invertit:

Descripció

This problem is reproduced in Clearance 3.2.1 and Nanostation M5 XM. When LAN and MESH role (12 VID tagged) is selected on wired interface, the BMX6 shows (bmx6 -c links) txRate=0 rxRate=100, so egress tagged frames are not transmitted to adjacent node.

Some tests were done. The original /etc/config/network showed:

config device 'lan_12'
option type '8021q'
option name 'lan_12'
option ifname 'br-lan'
option vid '12'
option proto 'static'

if this section is replaced by:

config device 'lan_12'
option type '8021q'
option name 'lan_12'
option ifname 'eth0'
option vid '12'
option proto 'static'

the problem seems to be solved.

Actions

També disponible a: Atom PDF